Thermal Diffusivity Estimation

Thermal Diffusivity may be estimated from a combination of the calculated thermal conductivity value (which is inversely related to the diffusivity) in conjunction with estimates of the specific heat, density and moisture content of the test bore. The thermal diffusivity reflects the rate of conductive heat transfer in the soil and helps determine the impact of neighboring borehole interactions on the final geothermal loopfield design.